PRESS    |   CONTACT US

                                                                                                   Home        Generators        Solar          Wind       Gasification


7, 12, 15KW Automatic Standby Generators

  • Quiet, powerful Generac OHVI single-cylinder or V-Twin engines fueled by natural gas or LP gas.
  • UL Listed remote-mounted pre-wired automatic transfer switch with 8, 10 or 12 circuit emergency load center for fast and efficient unattended transfer to generator when utility power fails.
  • A standard weather protective enclosure with sound-absorbing panels protects generator from harmful weather and also reduces exterior noise levels. Includes key locks for security.
  • Hinged top and removable front panel for easy serviceability.
  • Built-in charger maintains battery at optimum performance level.
  • Automatic safety shutdowns protect engine and generator in event of low oil pressure, high temperature, overspeed and/or overcrank.
  • Automatic seven-day exerciser runs the system for twelve minutes weekly to maintain top running condition.
  • Installation system includes the pre-wired automatic transfer switch with built-in load center, 30' 
    2 ' wiring harnesses, pre-wired external connection box, 1' flexible fuel line.
 
Generator Set
Model Number 04389 04456 04390
Rated Power LP (kW) 7 12 15**
Rated Power NG (kW) 6 12 13
Voltage @ 60 Hz 120/240 120/240 120/240
Phase Single Single Single
Frequency 60 Hz 60 Hz 60 Hz
Amps LP 58.3/29.2 100.0/50.0 125.0/62.5
Amps NG 50.0/25.0 100.0/50.0 108.3/54.2
Engine/Alternator RPM 3600/3600 3600/3600 3600/3600
Engine 410 cc.
14.5 HP
Generac OHVI
Single Cylinder
992 cc.
30 HP
Generac OHVI
V-Twin
992 cc.
30 HP
Generac OHVI
V-Twin
EPA/CARB Certified Yes Yes Yes
Fuel Natural Gas/
LP Vapor
Natural Gas/
LP Vapor
Natural Gas/
LP Vapor
Engine Cooling Air Air Air
UL2200 Yes Yes Yes
Canadian UL Yes Yes Yes
Main Line Circuit Breaker 40 Amp 50 Amp 60 Amp
Dimensions (L" x W" x H") 48 x 24 x 28-1/4 48 x 24 x 28-1/4 48 x 24 x 28-1/4
Unit Wt. (lbs.) 452 470 487


 
Controls
Start/Stop Control Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection.
Automatic Low Oil Shutdown Standard
Overspeed Shutdown Standard, 72 Hz
Overcrank Protection Standard
Automatic Voltage Regulator with Over-Voltage Protection Standard
Engine Warmup 10 seconds
Engine Cool-Down 1 minute
Safety Fuse Standard
Starter Lockout Starter cannot re-engage until 5 seconds after the engine has stopped
2 Amp Timed Trickle Battery Charger Standard
Auto Switch Utility failure/7 day exercise
Off Switch Stops unit. Power is removed. Control and charger still operate
Manual / test Start with starter control, unit stays on. If utility fails,transfer to load takes place


 
Transfer Switch
No. of Poles 2
Current Rating (amps) 100
Voltage Rating (VAC) 250
Utility Voltage Monitor (fixed)
Pick-up
Drop out

80%
60%
Return to Utility Approx. 13 seconds
Exercises 7 minutes weekly Standard
UL Listed Standard
Dimensions (H" x W" x D") 26.5 x 12.5 x 7
 
*Includes Transfer Switch

 

 

Request a Quote  


See how the Guardian standby generator works!

To view our online brochure click here.

 

 

 

copyright 2003-2006 - EnCom Group. All rights reserved