7,
12, 15KW Automatic
Standby Generators
- Quiet, powerful Generac OHVI
single-cylinder or V-Twin engines fueled by natural gas or LP
gas.
- UL Listed remote-mounted
pre-wired automatic transfer switch with 8, 10 or 12 circuit
emergency load center for fast and efficient unattended transfer
to generator when utility power fails.
- A standard weather protective
enclosure with sound-absorbing panels protects generator from
harmful weather and also reduces exterior noise levels. Includes
key locks for security.
- Hinged top and removable front
panel for easy serviceability.
- Built-in charger maintains
battery at optimum performance level.
- Automatic safety shutdowns
protect engine and generator in event of low oil pressure, high
temperature, overspeed and/or overcrank.
- Automatic seven-day exerciser
runs the system for twelve minutes weekly to maintain top
running condition.
- Installation system includes the
pre-wired automatic transfer switch with built-in load center,
30'
2 ' wiring harnesses, pre-wired external connection box, 1'
flexible fuel line.
 |
 |
|
 |
 |
Generator
Set |
 |
 |
| Model
Number |
04389 |
04456 |
04390 |
| Rated
Power LP (kW) |
7 |
12 |
15** |
| Rated
Power NG (kW) |
6 |
12 |
13 |
| Voltage
@ 60 Hz |
120/240 |
120/240 |
120/240 |
| Phase |
Single |
Single |
Single |
| Frequency |
60
Hz |
60
Hz |
60
Hz |
| Amps
LP |
58.3/29.2 |
100.0/50.0 |
125.0/62.5 |
| Amps
NG |
50.0/25.0 |
100.0/50.0 |
108.3/54.2 |
| Engine/Alternator
RPM |
3600/3600 |
3600/3600 |
3600/3600 |
| Engine |
410
cc.
14.5 HP
Generac OHVI
Single Cylinder |
992
cc.
30 HP
Generac OHVI
V-Twin |
992
cc.
30 HP
Generac OHVI
V-Twin |
| EPA/CARB
Certified |
Yes |
Yes |
Yes |
| Fuel |
Natural
Gas/
LP Vapor |
Natural
Gas/
LP Vapor |
Natural
Gas/
LP Vapor |
| Engine
Cooling |
Air |
Air |
Air |
| UL2200 |
Yes |
Yes |
Yes |
| Canadian
UL |
Yes |
Yes |
Yes |
| Main
Line Circuit Breaker |
40
Amp |
50
Amp |
60
Amp |
| Dimensions
(L" x W" x H") |
48
x 24 x 28-1/4 |
48
x 24 x 28-1/4 |
48
x 24 x 28-1/4 |
| Unit
Wt. (lbs.) |
452 |
470 |
487 |
 |
 |
|
 |
 |
Controls |
 |
 |
| Start/Stop
Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90
seconds overcrank protection. |
| Automatic
Low Oil Shutdown |
Standard |
| Overspeed
Shutdown |
Standard,
72 Hz |
| Overcrank
Protection |
Standard |
| Automatic
Voltage Regulator with Over-Voltage
Protection |
Standard |
| Engine
Warmup |
10
seconds |
| Engine
Cool-Down |
1
minute |
| Safety
Fuse |
Standard |
| Starter
Lockout |
Starter
cannot re-engage until 5 seconds after the
engine has stopped |
| 2
Amp Timed Trickle Battery Charger |
Standard |
| Auto
Switch |
Utility
failure/7 day exercise |
| Off
Switch |
Stops
unit. Power is removed. Control and charger
still operate |
| Manual
/ test |
Start
with starter control, unit stays on. If
utility fails,transfer to load takes place |
|
 |
 |
|
 |
 |
Transfer
Switch |
 |
 |
| No.
of Poles |
2 |
| Current
Rating (amps) |
100 |
| Voltage
Rating (VAC) |
250 |
Utility
Voltage Monitor (fixed)
Pick-up
Drop out |
80%
60% |
| Return
to Utility |
Approx.
13 seconds |
| Exercises
7 minutes weekly |
Standard |
| UL
Listed |
Standard |
| Dimensions
(H" x W" x D") |
26.5
x 12.5 x 7 |
|
*Includes Transfer Switch
|
|
Request
a Quote

See
how the Guardian standby generator works!
To view our online brochure click
here.
|